ECO Sampling Valve
The AWH ECO version is the economical entry into the AWH product portfolio. Suitable for product sampling of fluids from tanks and pipelines in systems of the food and beverage industry. The sampler is available in screw-in and weldon versions. It is sealed with a PTFE stopper that closes near the product.
Material | contact with product: 1.4404 (316L) |
Seal ring | plugs: PTFE, O-Ring: EPDM |
Surfaces | contact with product: Ra ≤ 0.8 μm |
Operating pressure | max. 10 bar / 145 psi |
Permissible operating temperature | max. 80°C / 176°F; CIP cleaning up to 90°C / 194°F max. unswitched, short-term 30 min.; SIP cleaning up to 135°C / 275°F max. unswitched, short-term 30 min. |
Product sampling | Hose connection (OD 10 mm) Inside diameter approx. 6.5 mm |
Connections | Welded version for pipe DN15 (29 x 1.5 mm) External thread R 1/2" |
Actuation | manual |
Technical Document
No related documents.
Video